MTD 951-14972 Engine Carburetor Solenoid Valve

SKU: 951-14972 Brand: Availability:
Out of Stock
(0)

$58.01


Have a Question? +1 (866) 963-0907

Description

The MTD 951-14972 Carburetor Solenoid Valve works with compatible engine element systems to regulate fuel flow. It functions through an electrically powered mechanism to open and shut the fuel passage, ensuring a proper fuel supply during engine operation. It is mounted on the carburetor assembly and assists in controlling the amount that enters the combustion system. It can be designed to allow for steady fuel management, aid in smooth engine starts, and aid in proper functioning of the fuel delivery process for consistent performance.

Dimensions:

  • Weight: 2 lbs

More Information:

The MTD 951-14972 Engine Carburetor Solenoid Valve helps regulate fuel flow to the carburetor. A faulty solenoid valve may lead to poor starting, engine shutdown, or inconsistent operation during mowing.

Common Symptoms:

• Hard starting caused by a defective carburetor solenoid valve.

• Engine dies shortly after ignition.

• No audible solenoid activation when the key is turned.

• Fuel flow interruption from a sticking solenoid.

• Rough engine performance due to inconsistent valve movement.

Hard Starting

Quick Check: Turn the ignition on and verify the solenoid activates with a clicking sound.

Fix Suggestion: Replace the faulty solenoid if it fails to operate correctly.

Prevention Tip: Inspect electrical connections during regular maintenance.

Engine Dies Shortly After Ignition

Quick Check: Confirm continuous electrical power reaches the solenoid while running.

Fix Suggestion: Replace the valve if it loses operation after startup.

Prevention Tip: Keep the charging and ignition systems in good condition.

No Solenoid Activation

Quick Check: Check the connector for loose terminals or corrosion.

Fix Suggestion: Repair damaged wiring or install a replacement solenoid if necessary.

Prevention Tip: Prevent moisture from entering electrical connectors.

Fuel Flow Interruption

Quick Check: Examine for debris affecting solenoid movement.

Fix Suggestion: Clean the carburetor and replace the sticking valve if required.

Prevention Tip: Store fuel properly and avoid contaminated gasoline.

Customer Experience: After installing the MTD 951-14972 Engine Carburetor Solenoid Valve, my mower stopped shutting off suddenly and now runs much more reliably throughout the operation.

Disclaimer: Troubleshooting guidance provided for reference only.