Powermate E100095 Air Compressor Pressure Switch

SKU: E100095 Brand: Availability:
Out of Stock
(0)

$64.74 Price reduced from $67.95
Save $3.21


Have a Question? +1 (866) 963-0907

Description

The Powermate E100095 Air Compressor Pressure Switch is a high quality switch that regulates air compressor pressure levels for efficient operation. In doing this, it automatically controls the on/off functionality, based on pressure levels, allowing the compressor to stay in the better pressure within a given range. This switch prevents over pressurization and increases safety and compressor life. It is ideal for home and professional use and improves compressor efficiency, lowers energy consumption and reduces damage. It was constructed of strong materials while providing dependable, reliable performance on numerous tasks involved with tire inflation or pneumatic tools.

More Information:

The Powermate E100095 Air Compressor Pressure Switch Monitors tank pressure and automatically turns the compressor motor on and off at preset pressure levels. A properly functioning pressure switch supports maintain consistent air pressure, protects the compressor from unnecessary cycling, and supports reliable performance.

This part can help with the following issues:

• Compressor fails to start when tank pressure drops.

• Compressor cycles on and off too frequently.

• Motor continues running after the tank reaches full pressure.

• Pressure switch clicks but the motor does not respond.

• Air pressure is not maintained within the normal operating range.

Compressor Will Not Start

Quick Check: Verify that power is reaching the pressure switch and inspect the switch terminals for damage.

Fix Suggestion: Replace the pressure switch if it fails to close the electrical circuit when tank pressure falls.

Prevention Tip: Keep electrical connections clean and protect the switch from moisture.

Motor Fails to Shut Off

Quick Check: Observe whether the compressor continues running after the cut-out pressure is reached.

Fix Suggestion: Inspect the pressure switch contacts and replace the switch if it no longer disengages properly.

Prevention Tip: Regularly monitor operating pressure to detect abnormal cycling early.

Frequent Cycling

Quick Check: Listen for repeated short on/off cycles during normal compressor use.

Fix Suggestion: Test the pressure switch for proper cut-in and cut-out operation and replace it if switching becomes inconsistent.

Prevention Tip: Maintain the recommended tank pressure and inspect the air system for leaks.

Delayed Pressure Response

Quick Check: Compare the compressor's start and stop points with the specified pressure settings.

Fix Suggestion: Install a new pressure switch if pressure response becomes slow or erratic.

Prevention Tip: Periodically inspect the pressure switch for dirt, corrosion, or worn electrical contacts.

Customer Experience: Many compressor owners shared that replacing the Powermate E100095 pressure switch restored automatic compressor cycling, eliminated irregular pressure control, and improved day-to-day operation.

Disclaimer: Troubleshooting guidance provided for reference only.